 Emergency Stop Devices
Cable (Rope) Pull Switches
Lifeline 3 Specifications
Standards Approvals Safety Contact Designation/Utilization Cat. A600/AC-15 (Ue) (Ie) N600/DC-13 (Ue) (Ie) Thermal Current (lth) Minimum Current Safety Contact Gap Rtd. Impulse Withstand Voltage Pollution Degree Max. Actuation Frequency Case Material Eye Nut Material Indicator Material Protection Conduit Entry Operating Temperature Operation Force Tensioning Force to Run Position Tensioning Force to Lockout Max. Cable Span Between Switches Fixing (mounting holes) Mounting Mechanical Life Weight Colour EN 418, ISO 13850, ISOTR 12100, IEC 60947-5-1, IEC 60947-5-5 CE marked for all applicable directives, cULus and TUV 2 N.C. or 3 N.C. or 4 N.C. direct opening action 600V 500V 240V 120V 1.2A 1.4A 3A 6A 600V 500V 250V 125V 0.4A 0.55A 1.1A 2.2A 10 A 5 V 5 mA >2 x 2mm (0.078in) (Uimp) 2500 V 3 1 cycle/s Heavy-duty die-cast aluminium alloy (LM24) Stainless steel Glass filled nylon IP67 1 x 1/2in NPT, 1 x M20, quickdisconnect style -25C to +80C (-13F to +176F) <125N (28.1lb) (300mm deflection) 103N (23.17lb) typical 188N (42.3lb) typical 30m (98.42ft) 4 x M5 Any position 1,000,000 610g (1.34lb) Yellow body, blue reset button
Description
The Lifeline 3 is a cable (rope) operated emergency stop device designed to meet the stringent requirements of EN 418 (Safety of Machinery--Emergency Stop Equipment). The Lifeline 3 system can be installed along or around awkward machinery such as conveyors and provides a constant-access emergency-stop facility. The Lifeline 3 is the only device of its kind to incorporate the following features in one unit making it the most versatile cable switch on the market. 1. The positive-mode mechanism ensures that the contacts are immediately latched open on actuation and can only be reset by the intentional action of turning the blue reset knob. The design also protects against nuisance tripping and the effects of thermal expansion. 2. The cable-status indicator makes the system easy to set up and maintain for spans up to 30m (98ft). 3. Four sets of contacts are provided: 2 N.C. + 2 N.O., 3 N.C. + 1 N.O., or 4 N.C. contacts. 4. Sealed to IP67 with rugged construction using die-cast alloy and stainless steel to withstand harsh conditions.
Features
* * * * * * Switches up to 30m (98ft) span Universal mounting and operation Switch lockout on cable pulled and cable slack Cable-status indicator on switch lid Industry standard fixing centres to DIN/EN 50041 Quick disconnect styles available.
Important: It is recommended that the LRTS (Lifeline Rope Tensioning System) should be used with the Lifeline 3 cable rope switch.
Typical Applications
6-4
Emergency Stop Devices
Cable (Rope) Pull Switches
Lifeline 3 Product Selection
Catalogue Number Safety Contacts 2 N.C. 3 N.C. 4 N.C. Auxiliary Contacts 2 N.O. 1 N.O. -- 1/2in NPT Conduit 440E-D13120 440E-D13114 440E-D13108 M20 Conduit 440E-D13118 440E-D13112 440E-D13106 Quick Disconnect 440E-D13132 440E-D13124 440E-D13136 889M-F12X9AE-2
Recommended Standard Cable Connector/Cordset (2m (6.5ft) (see page 15-13).
Accessories
Description P. Bolt Complete M8 x 1.25 Thread Size 58mm (2.28in) Threaded Length 12mm (0.47in) Dia. Eye 95mm (3.74in) Overall Length Lifeline Tensioner Spring 19mm (0.75in) Diameter 210mm (8.27in) Overall Length 50N Force Inside Corner Pulley Catalogue Number
440E-A17003
440E-A13078
440A-A17101
Outside Corner Pulley
440A-A17102
6-5
Emergency Stop Devices
Cable (Rope) Pull Switches
Lifeline 3 Application Details--mm (inches)
Lifeline 3 Cable Grips 1 Tension 125 (5) Indicator 2-3m (6-9ft) 2 30m (98ft) Tensioner 2 P. Bolts 1 3
Polypropylene-covered steel cable 2 F d
2-3m (6-9ft)
125 (5)
Reset Knob 4
Lifeline 3 1 Tension 125 (5) Indicator 2-3m (6-9ft) 2 F d 2-3m (6-9ft) 125 (5) 2 1
Tensioner Spring
5
6 Wall
2 10m (32ft)
Notes: 1. The first and last P. Bolt must be located as close as possible to the switch eyelet while maintaining adequate clearance (125mm/5in) from the cable grips to allow free movement. This ensures a straight and efficient pulling action on the switches. 2. Additional P. Bolts, spaced 2-3m (6-9ft) apart, help keep the perpendicular pull force, F, and distance, d, within IEC60947-5-5 specifications of 200N (45lbs) and 400mm (15.75in). 3. We recommend using a switch at both cable ends, especially in applications with long cable runs or cable runs going around bends. This helps ensure that the safety function is fulfilled upon actuation of the cable in any direction. 4. ISO13850 (EN418) requires that the full length of cable to be within view when the reset is turned to the run position or the machine must be inspected over the whole length of the cable, both before and after resetting. 5. On shorter cable runs (max 10m), a Lifeline tensioner spring may be used at one end of the span. The installation must be such that the above requirements can be met. When a spring is used, the last P. Bolt must be located as close as possible to the spring while maintaining adequate clearance (125mm/5in) from the cable grips to allow free movement. This is intended to help to ensure that a pull near the end of the cable will be between P. Bolts. This should result in operation of the switch contacts instead of only the spring moving. 6. Careful attention is required for the design of the installation to ensure that the cable is not likely to become trapped or snagged. This is especially important when using a tensioner spring because a cable snag between the location of the pull and the switch could prevent the actuation of the safety function. 7. It is essential that when the installation is complete, a thorough functional test is made. This should include checking all types and directions of pull over the length of the cable as well as checking for slack-cable tripping.
6-6
Emergency Stop Devices
Cable (Rope) Pull Switches
Lifeline 3 Approximate Dimensions--mm (inches)
Dimensions are not intended to be used for installation purposes.
56 (2.2) 43 (1.69)
10.5 (0.41)
60 (2.36)
204 (8.03) 4 x M5 mounting holes
40 (1.57
30 (1.18)
Typical Wiring Diagrams
4 N.C. style 3 N.C. + 1 N.O. style 2 N.C. + 2 N.O. style
41
31
21
11
43
31
21
11
43
33
21
11
42
32
22
12
44
32
22
12
44
34
22
12
4 N.C. Connector Pinout 1 3 4 6 7 8 9 10 12 Terminal 11 12 21 22 31 32 41 42 Contact N.C. N.C. N.C. N.C.
3 N.C. + 1 N.O. Terminal 11 12 21 22 31 32 43 44 Ground Contact N.C. N.C. N.C. N.O.
2 N.C. + 2 N.O. Terminal 11 12 21 22 33 34 43 44 Contact N.C. N.C. N.O. N.O.
8 7 6 5 12
9 11 4
1 10 2 3
Contact Action
Contact Open Contact Closed
4 N.C. style 3 N.C. + 1 N.O. style 2 N.C. + 2 N.O. style
0mm 3 11/12 21/22 31/32 41/42
6
9
10.5 13.5
0mm 11/12 21/22 31/32 43/44
3
6
9
10.5 13.5
0mm 11/12 21/22 33/34 43/44
3
6
9
10.5 13.5
Cable Slack Cable Tension Cable Pulled Lockout Lockout Range
Cable Slack Cable Tension Cable Pulled Lockout Range Lockout
Cable Slack Lockout
Cable Tension Range
Cable Pulled Lockout
6-7


▲Up To Search▲   

 
Price & Availability of 440E-D13106

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X